Model: TX2 – TEZ2

EXPANSION VALVE T Series Feature: Wide temperature range; Interchangeable orifice; Orifice can be chose according to refrigerant and capacity; Suit to all HCFC and HFC refrigerant: R12,R22,R134A,R404A,R507A,R407…

Model series
TX2 / TEX2 / TN2 / TEN2 / TS2 / TES2 / TF2 / TEF2 / TY2 / TEY2 / TZ2 / TEZ2
Refrigerant
R12, R22, R134A, R404A, R507, R407C, R502
Equalizer
Internal or external
Capillary length
1.5 m
MOQNegotiable
Lead TimeNegotiable
PaymentT/T, L/C
PortShanghai / Ningbo

The manual is generated automatically from the latest product data — includes overview, features, full specifications and our contact details.

Product Description

The T series is a thermostatic expansion valve for small and medium refrigeration and air-conditioning circuits. It meters liquid refrigerant into the evaporator at the rate the load requires, holding a constant superheat at the evaporator outlet, and it does this without any electrical supply - the bulb clamped to the suction line provides the signal.

The model code carries two pieces of information that make selection straightforward. The first letter states the refrigerant: T for R22, N for R134a, S for R404A and R507, F for R12, Y for R502 and Z for R407C. The E prefix marks the externally equalised version, used where the evaporator has a distributor or a significant pressure drop. So TX2 and TEX2 are both R22 valves, the second with external equalisation, and the same pattern runs through all twelve models.

Capacity is set by the orifice, not by the body: the valve accepts interchangeable orifices from #X up to #6, covering 0.38 kW to 16.7 kW (0.11 to 4.9 RT). One body can therefore be re-orificed when a system is modified instead of being replaced. The capacity table is published for each refrigerant across the full evaporating range, and the orifice has to be chosen from that table at the design evaporating and condensing temperatures.

Connections are 3/8 inch inlet by 1/2 inch outlet with a 1.5 m capillary - the standard arrangement for small condensing units, display cases, water chillers and cold room evaporators. Static superheat is adjustable from the bottom of the valve with the cap removed.

Installation points: keep the bulb in intimate contact with a clean horizontal section of suction line and insulate it from ambient; mount the body upright; and on externally equalised versions take the equaliser from the suction line downstream of the bulb.

Frequently asked questions

What is the difference between internal and external equalisation?+
An internal equaliser senses pressure at the valve outlet. That is adequate for a single evaporator with a small pressure drop. An external equaliser senses pressure at the evaporator outlet and compensates for the drop across the distributor and coil, so it is the usual choice on larger or multi-circuit coils. In the T series this is the difference between TX2 and TEX2: the E versions carry the external connection.
How do I set the superheat on a T series valve?+
Bring the system to a steady condition first, then measure superheat at the evaporator outlet. Adjust the superheat screw a quarter turn at a time and allow 15–20 minutes to stabilise before measuring again; clockwise increases superheat. If you cannot reach a stable value across the load range, check the orifice and the refrigerant charge code before blaming the setting — an undersized orifice behaves like a badly adjusted valve.
Which refrigerants and charges are available?+
The T series covers R12, R22, R134a, R404A, R507, R407C and R410A. The power element is refrigerant-specific, so the charge code must match the refrigerant and the evaporating range of your application. Give us the refrigerant and evaporating temperature when ordering and we will confirm the correct charge code rather than shipping a generic valve.

Key Features

  • ✓Wide temperature range with interchangeable orifice
  • ✓Orifice selectable by refrigerant and required capacity
  • ✓Suitable for all HCFC and HFC refrigerants
  • ✓Internal or external equalizer to match different evaporator designs

Technical Specifications

Model seriesTX2 / TEX2 / TN2 / TEN2 / TS2 / TES2 / TF2 / TEF2 / TY2 / TEY2 / TZ2 / TEZ2
RefrigerantR12, R22, R134A, R404A, R507, R407C, R502
EqualizerInternal or external
Capillary length1.5 m
Connection (inlet x outlet)3/8" x 1/2"
OrificeInterchangeable, #X and #0 – #6
Nominal capacity0.11 – 4.9 RT / 0.38 – 16.7 kW (orifice #X – #6)