Pressure Control - KP Series

الموديل: KP1 – KP15

For use with fluorinated refrigerants as well as with a air and water Allowable Fluid Temp.:-10c~+110° Various contact functions available With SPDT contact mechanism Renovated micro-switch structu…

Model range
KP1, KP5, KP35, KP38, KP15 (single and dual pressure)
Pressure range
-0.9 – 32 bar
Differential range
0.7 – 4 bar (fixed 0.7 / 4 bar); KP38A 1.8 – 6.0 bar
Reset
Auto or manual
أقل كميةNegotiable
مدة التسليمNegotiable
الدفعT/T, L/C
الميناءShanghai / Ningbo

يُنشأ الدليل تلقائياً من أحدث بيانات المنتج — نظرة عامة والميزات والمواصفات الكاملة وبيانات التواصل.

وصف المنتج

The KP series is the general-purpose pressure switch for refrigeration and air-conditioning plant: a single-pole double-throw contact, a bellows sensing element and a setting that is adjusted with a screwdriver on site.

Five families cover the usual duties. KP1 and KP35 are low pressure controls, used to cut the compressor out on low suction and to restart it on rise - the standard pump-down and low-pressure protection arrangement. KP5 and KP38 are high pressure controls, cutting out on rising discharge pressure. KP15 is the dual version, with both functions in one body, which is what most small condensing units actually use.

The pressure range runs from -0.9 bar to 32 bar, with differentials from 0.7 to 4 bar depending on model; the KP38A offers a wider 1.8 to 6.0 bar differential for high pressure duty. Reset is automatic or manual depending on the variant - manual reset is normally chosen for high pressure cut-outs, so that the fault has to be acknowledged rather than the compressor restarting into the same condition.

Contact arrangements include SPDT and SPDT with a low-pressure signal or with both low and high signal outputs, for plant that needs to report state to a controller as well as switch the compressor.

Connection is 1/4 inch NPT or 1/4 inch G, with specials on request, and the allowable fluid temperature is -10 C to +110 C.

Setting notes: set the cut-out below the normal operating point by a margin that reflects the ambient swing, not by a fixed number, and check the differential against the compressor's minimum run time - too narrow a differential short-cycles the machine.

الميزات الرئيسية

  • ✓For fluorinated refrigerants, air and water
  • ✓Renovated micro-switch structure for reliable switching
  • ✓Low, high and dual-pressure versions with auto or manual reset
  • ✓SPDT contact with optional low-pressure and high-pressure signal outputs

المواصفات الفنية

Model rangeKP1, KP5, KP35, KP38, KP15 (single and dual pressure)
Pressure range-0.9 – 32 bar
Differential range0.7 – 4 bar (fixed 0.7 / 4 bar); KP38A 1.8 – 6.0 bar
ResetAuto or manual
Contact functionSPDT; SPDT + low signal; SPDT + low/high signal
Connection1/4" NPT or 1/4" G (special on request)
Allowable fluid temperature-10 ~ +110 °C

استفسر عن هذا المنتج

أخبرنا بكمية وجهد ونطاق الحرارة المطلوب — وستستلم عرض سعر خلال 24 ساعة.

We reply within 24 hours. Your information is kept confidential.