Solenoid Valve EVR Series
Model: EVR3 – EVR40
Feature DC24V. DC12V, AC110V, AC220V and Ac380v (8w coils are available if vou need 20W coil,please inform us of that when placing order Refrigerant:R12,R22;R134a,R404,R407C,R410,R502 Media Temperature:-40℃ ~ +110℃ …
- Model range
- EVR3, EVR6, EVR10, EVR15 (flare); EVR3(S) – EVR40(S) (solder)
- Coil voltage
- DC12V / DC24V / AC110V / AC220V / AC380V
- Refrigerant
- R12, R22, R134a, R404, R407C, R410A, R502
- Media temperature
- -40 °C ~ +110 °C
The manual is generated automatically from the latest product data — includes overview, features, full specifications and our contact details.
Product Description
The EVR series is the wider solenoid valve range, from EVR3 at the small end to EVR40(S) at the top, covering 2.2 kW to 503 kW on R404A and R22. That takes one valve family from small condensing units up to industrial pump-circulation circuits and large cold stores.
Flare versions (EVR3, EVR6, EVR10, EVR15) cover 1/4 inch to 5/8 inch; solder versions run from 1/4 inch to 2-1/8 inch, so the range fits both split-system tube and plant-room pipework. Coils are available for DC12V, DC24V, AC110V, AC220V and AC380V, and the electrical part is separate from the body, which means a coil can be replaced without opening the refrigerant circuit.
The valve is rated for -40 C to +110 C media temperature, 40 bar working pressure and 100,000 cycles, and is compatible with R12, R22, R134a, R404A, R407C, R410A and R502 - the same specification as the C series, so the two ranges can be mixed on one system.
Because capacity is published per size and per refrigerant, selection has to start from the required capacity at the working pressure difference, not from the pipe diameter. On pump-down circuits the valve must also close against the pump-down pressure, and on hot gas lines the available differential is small, which usually pushes the selection one or two sizes up.
Installation: coil uppermost, flow arrow respected, strainer upstream, and on the larger sizes support the body independently of the pipework so vibration does not load the solder joints.
Frequently asked questions
Which coil voltage should I choose?+
What differs in practice between AC and DC coils?+
Can an EVR valve be used on the suction line?+
Key Features
- ✓Direct-acting solenoid valve for refrigeration and air-conditioning lines
- ✓Flare version from 1/4" to 5/8", solder version up to 2-1/8"
- ✓Wide refrigerant compatibility including R410A and R407C
- ✓100,000 cycle service life with 40 bar maximum working pressure
Technical Specifications
| Model range | EVR3, EVR6, EVR10, EVR15 (flare); EVR3(S) – EVR40(S) (solder) |
| Coil voltage | DC12V / DC24V / AC110V / AC220V / AC380V |
| Refrigerant | R12, R22, R134a, R404, R407C, R410A, R502 |
| Media temperature | -40 °C ~ +110 °C |
| Max. working pressure | 40 bar |
| Service life | 100,000 cycles |
| Connection | Flare 1/4" – 5/8"; solder 1/4" – 2-1/8" |
| Nominal capacity | 2.2 – 503 kW (R404A / R22) |
Inquire About This Product
Tell us your requirement — quantity, voltage, temperature range — and receive a quotation within 24 hours.
Related Products
Expansion Valve T Series
TX2 – TEZ2Capillary length: 1.5 m
Connection (inlet x outlet): 3/8" x 1/2"
Maneurop horizontal valve/Rotalock valve/Stop valve
MV-01 – SV-09Valve body: 20×20 to 45×45 mm
M thread: 1"-14UNS to 2-1/4"-12UNF
CV CHECK VALVE
CV-6 – CVR-42Internal diameter: 4.8 – 31 mm
Kv value: 0.56 – 30.0 m³/h
Hand Valve
HV-02 – HV-07 / HV-02H – HV-06HThread (flare): 7/16" – 1-1/4"
Connection type: Flare or solder